Sabic Lexan ML7677A resin is Commercial grade for Polycarbonate in only nature color. Excellent processability, super high flow, flame retardant, UL rated V-1 at
TYPICAL PROPERTIES (1) | |||
MECHANICAL | Value | Unit | Standard |
Tensile Stress, yld, Type I, 50 mm/min | 69 | MPa | ASTM D 638 |
Tensile Stress, brk, Type I, 50 mm/min | 52 | MPa | ASTM D 638 |
Tensile Strain, yld, Type I, 50 mm/min | 5 | % | ASTM D 638 |
Tensile Strain, brk, Type I, 50 mm/min | 50 | % | ASTM D 638 |
Tensile Modulus, 50 mm/min | 2670 | MPa | ASTM D 638 |
Flexural Stress, yld, 1.3 mm/min, 50 mm span | 98 | MPa | ASTM D 790 |
Flexural Modulus, 1.3 mm/min, 50 mm span | 2300 | MPa | ASTM D 790 |
Tensile Stress, yield, 50 mm/min | 70 | MPa | ISO 527 |
Tensile Stress, break, 50 mm/min | 54 | MPa | ISO 527 |
Tensile Strain, yield, 50 mm/min | 5 | % | ISO 527 |
Tensile Strain, break, 50 mm/min | 70 | % | ISO 527 |
Tensile Modulus, 1 mm/min | 2650 | MPa | ISO 527 |
Flexural Stress, yield, 2 mm/min | 105 | MPa | ISO 178 |
Flexural Modulus, 2 mm/min | 2600 | MPa | ISO 178 |
IMPACT | Value | Unit | Standard |
Izod Impact, notched, 23°C | 40 | J/m | ASTM D 256 |
Izod Impact, notched, -30°C | 37 | J/m | ASTM D 256 |
Instrumented Impact Total Energy, 23°C | 65 | J | ASTM D 3763 |
Izod Impact, unnotched 80*10*3 +23°C | 182 | kJ/m² | ISO 180/1U |
Izod Impact, unnotched 80*10*3 -30°C | 181 | kJ/m² | ISO 180/1U |
Izod Impact, notched 80*10*3 +23°C | 4 | kJ/m² | ISO 180/1A |
Izod Impact, notched 80*10*3 -30°C | 4 | kJ/m² | ISO 180/1A |
Charpy 23°C, V-notch Edgew 80*10*3 sp=62mm | 4 | kJ/m² | ISO 179/1eA |
Charpy -30°C, V-notch Edgew 80*10*3 sp=62mm | 4 | kJ/m² | ISO 179/1eA |
Charpy 23°C, Unnotch Edgew 80*10*3 sp=62mm | 131 | kJ/m² | ISO 179/1eU |
Charpy -30°C, Unnotch Edgew 80*10*3 sp=62mm | 130 | kJ/m² | ISO 179/1eU |
THERMAL | Value | Unit | Standard |
Vicat Softening Temp, Rate B/50 | 114 | °C | ASTM D 1525 |
HDT, 1.82 MPa, 3.2mm, unannealed | 94 | °C | ASTM D 648 |
CTE, -40°C to 40°C, flow | 6.5E-05 | 1/°C | ASTM E 831 |
CTE, -40°C to 40°C, xflow | 6.6E-05 | 1/°C | ASTM E 831 |
CTE, 23°C to 80°C, flow | 7.2E-05 | 1/°C | ISO 11359-2 |
CTE, 23°C to 80°C, xflow | 7.4E-05 | 1/°C | ISO 11359-2 |
Vicat Softening Temp, Rate B/50 | 111 | °C | ISO 306 |
Vicat Softening Temp, Rate B/120 | 114 | °C | ISO 306 |
HDT/Af, 1.8 MPa Flatw 80*10*4 sp=64mm | 97 | °C | ISO 75/Af |
PHYSICAL | Value | Unit | Standard |
Specific Gravity | 1.23 | - | ASTM D 792 |
Mold Shrinkage, flow, 3.2 mm (5) | 0.6 - 0.8 | % | SABIC Method |
Mold Shrinkage, xflow, 2.3-4.6 mm (5) | 0.6 - 0.8 | % | SABIC Method |
Melt Flow Rate, 260°C/2.16 kgf | 23 | g/10 min | ASTM D 1238 |
Melt Flow Rate, 300°C/1.2 kgf | 45 | g/10 min | ASTM D 1238 |
Density | 1.23 | g/cm³ | ISO 1183 |
Water Absorption, (23°C/sat) | 0.28 | % | ISO 62 |
Moisture Absorption (23°C / 50% RH) | 0.35 | % | ISO 62 |
Melt Volume Rate, MVR at 300°C/1.2 kg | 43 | cm³/10 min | ISO 1133 |
FLAME CHARACTERISTICS | Value | Unit | Standard |
UL Compliant, 94V-1 Flame Class Rating (3)(4) | 2 | mm | UL 94 by GE |
Source GMD, last updated:2009/10/12 |
Parameter | |||
Injection Molding | Value | Unit | |
Drying Temperature | 80 - 90 | °C | |
Drying Time | 3 - 4 | hrs | |
Drying Time (Cumulative) | 8 | hrs | |
Maximum Moisture Content | 0.04 | % | |
Melt Temperature | 245 - 275 | °C | |
Nozzle Temperature | 245 - 275 | °C | |
Front - Zone 3 Temperature | 245 - 275 | °C | |
Middle - Zone 2 Temperature | 220 - 265 | °C | |
Rear - Zone 1 Temperature | 220 - 255 | °C | |
Mold Temperature | 60 - 80 | °C | |
Back Pressure | 0.3 - 0.7 | MPa | |
Screw Speed | 40 - 70 | rpm | |
Shot to Cylinder Size | 30 - 80 | % | |
Vent Depth | 0.038 - 0.076 | mm | |
Source GMD, last updated:2009/10/12 | |||
THESE PROPERTY VALUES ARE NOT INTENDED FOR SPECIFICATION PURPOSES. | |||
PLEASE CHECK WITH YOUR (LOCAL SALES OFFICE) FOR AVAILABILITY IN YOUR REGION | |||
(1) Typical values only. Variations within normal tolerances are possible for various colors. All values are measured after at least 48 hours storage at 23°C/50% relative humidity. All properties, except the melt volume and melt flow rates, are measured on injection molded samples. All samples tested under ISO test standards are prepared according to ISO 294. |
|||
(2) Only typical data for selection purposes. Not to be used for part or tool design. | |||
(3) This rating is not intended to reflect hazards presented by this or any other material under actual fire conditions. | |||
(4) Internal measurements according to UL standards. | |||
(5) Measurements made from laboratory test coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article. |
For more information please download the datasheet |
|
Sabic Lexan ML7677A.pdf |
Get The Latest Quotation
First-level distribution source in South China Reduce procurement costs, improve supply stability, Help you find the most suitable engineering plastic materials
Click to consult and get the latest quotation within 24 hours! |